#ExistMethodology>
| Methodology: |
Electromagnetic Mechanical Clot Detection
|
*ExistMethodology>
#ExistPerformed>
| Performed: |
Sun-Sat
|
*ExistPerformed>
#ExistReported>
| Reported: |
1-2 days
|
*ExistReported>
#ExistSpecRequirements>
| Specimen Required: |
#ExistCollect>Collect: One 5 mL lt. blue (3.2% sodium citrate).
*ExistCollect>
#ExistTransport>Transport: 1 mL platelet-poor plasma (lt. blue, 3.2% sodium citrate), frozen. (Min: 0.5 mL) Submit specimen in an ARUP Standard Transport Tube.
*ExistTransport>
#ExistPedCollectTransport>Pediatric Collection/Transport: Collect one 1.8 mL lt. blue. Transport 1 mL platelet-poor plasma (lt. blue, sodium citrate), frozen. (Min: 0.5 mL)
*ExistPedCollectTransport>
#ExistRemarks>Remarks: Separate plasma from cells ASAP and freeze for transport.
*ExistRemarks>
#ExistConditions>Unacceptable Conditions: Serum, clotted or hemolyzed specimens. Specimens ambient or refrigerated greater than four hours.
*ExistConditions>
#ExistStability>Stability: Ambient: 4 hours; Refrigerated: 4 hours; Frozen: 1 week *ExistStability>
|
*ExistSpecRequirements>
|
|