#ExistCollect>Collect: Light blue (sodium citrate). Refer to Specimen Handling at aruplab.com for hemostasis/thrombosis specimen handling guidelines.
*ExistCollect>
#ExistSPECIMENPREPARATION>Specimen Preparation: Transfer 2 mL platelet poor plasma to an ARUP Standard Transport Tube. (Min: 0.5 mL)
*ExistSPECIMENPREPARATION>
#ExistSPECTRANSPORT>Storage/Transport Temperature:CRITICAL FROZEN. Separate specimens must be submitted when multiple tests are ordered.
*ExistSPECTRANSPORT>
#ExistConditions>Unacceptable Conditions: Serum. Non-frozen or hemolyzed specimens.
*ExistConditions>
#ExistStability>Stability (collection to initiation of testing): After separation from cells: Ambient: 8 hours; Refrigerated: 8 hours; Frozen: 1 month *ExistStability>
#ExistInterpData>The presence of rheumatoid factor may lead to false-positive results with the D-Dimer test. This test should not be used to rule out venous thromboembolism.
Maximal values less than 10 are rarely indicative of DIC.
Results are reported in Fibrinogen Equivalent Units (FEU).
*ExistInterpData>