Total Inhibin : 2002550

Mnemonic: T INHIBIN

Ordering Recommendation: Use with inhibin B levels to differentiate ovarian tumor with normal CA-125 from stromal or mucinous epithelial tumor. May be used for monitoring recurrence of stromal ovarian tumors.
Methodology: Enzyme-Linked Immunosorbent Assay
Performed: Varies
Reported: 4-7 days
Specimen Required: Collect: Serum separator tube or plain red.

Specimen Preparation: Transfer 2 mL serum to an ARUP Standard Transport Tube. (Min: 1 mL)

Storage/Transport Temperature: Frozen.

Unacceptable Conditions: Grossly hemolyzed specimens.

Stability (collection to initiation of testing): Ambient: Unacceptable; Refrigerated: Unacceptable; Frozen: 3 months

Reference Interval:
By report
CPT Code(s): 83520