ARUP's Laboratory Test Directory

Human Immunodeficiency Virus 2 Antibody Confirmation by Immunoblot : 0093272

Mnemonic: HIV 2 IBL

Methodology: Immunoblot
Performed: Varies
Reported: Within 14 days
Specimen Required: Collect:  One 5 mL plain red.

Transport:  1 mL serum at 2-8°C. (Min: 0.25 mL)

Submit specimen according to Biological Substance, Category B, shipping guidelines.


Pediatric Collection/Transport:  0.25 mL serum at 2-8°C.

Submit specimen according to Biological Substance, Category B, shipping guidelines.


Remarks:  Separate serum from cells ASAP. Plasma is acceptable. Avoid repeated freeze/thaw cycles.

Unacceptable Conditions:  Severely hemolytic, lipemic, or cadaveric specimens.

Stability:  After separation from cells: Ambient: 1 week; Refrigerated: 2 months; Frozen: Indefinitely
Reference Interval:
By report
Interpretive Data: Refer to report
CPT Code(s): 86689
 
 

 

 

 