#ExistMethodology>
| Methodology: |
Quantitative Electrochemiluminescent Immunoassay
|
*ExistMethodology>
#ExistPerformed>
| Performed: |
Sun-Sat
|
*ExistPerformed>
#ExistReported>
| Reported: |
Within 24 hours
|
*ExistReported>
#ExistSpecRequirements>
| Specimen Required: |
#ExistCollect>Collect: Serum separator tube or plasma separator tube. Also acceptable: Green (sodium or lithium heparin), lavender (EDTA), or pink (K2EDTA).
*ExistCollect>
#ExistSPECIMENPREPARATION>Specimen Preparation: Pooled specimens must be all serum or all plasma. Allow specimen to clot completely at room temperature and separate serum or plasma from cells ASAP or within 2 hours of collection. Transfer 1 mL serum or plasma to an ARUP Standard Transport Tube. (Min: 0.3 mL)
*ExistSPECIMENPREPARATION>
#ExistSPECTRANSPORT>Storage/Transport Temperature: Refrigerated.
*ExistSPECTRANSPORT>
#ExistConditions>Unacceptable Conditions: Hemolyzed specimens.
*ExistConditions>
#ExistStability>Stability (collection to initiation of testing): After separation from cells: Ambient: 8 hours; Refrigerated: 2 weeks; Frozen: 6 months
*ExistStability>
|
*ExistSpecRequirements>
|
|