ARUP's Laboratory Test Directory

Autoimmune Hepatitis Panel with Reflex to ANA IFA Titer : 0055356

Mnemonic: AIH

Methodology: Enzyme-Linked Immunosorbent Assay/Indirect Fluorescent Antibody
Performed: Sun, Tue, Thu
Reported: 2-4 days
Specimen Required: Collect:  One 4 mL serum separator tube.

Transport:  1 mL serum at 2-8°C. (Min: 0.5 mL)  Submit specimen in an ARUP Standard Transport Tube.

Pediatric Collection/Transport:  0.75 mL serum at 2-8°C.

Remarks:  Separate serum from cells ASAP.  Avoid repeated freeze/thaw cycles.

Stability:  After separation from cells: Ambient: 2 days; Refrigerated: 2 weeks; Frozen: 1 year
Reference Interval:
 
Test Number Components Reference Interval
0050080Anti-Nuclear Antibodies (ANA), IgG Screen with Reflex to IFA Titer None detected
0055248F-Actin (Smooth Muscle) Antibody, IgG 19 Units or less: Negative
20-30 Units: Weak Positive - Suggest repeat testing in two to three weeks with fresh specimen.
31 Units or greater: Positive - Suggestive of autoimmune hepatitis or chronic active hepatitis.
0055241Liver-Kidney Microsome - 1 Antibody, IgG 0.0-20.0 U: Negative
20.1-24.9 U: Equivocal
Greater than or equal to 25.0 U: Positive
0050065Mitochondrial M2 Antibody, IgG (ELISA) < 1.0 Units: No antibody detected
1.0-1.3 Units: Inconclusive
> 1.3 Units: Positive
 

Note: Specimens are screened for ANA using ELISA. If antibodies are detected, then an IFA titer using HEp-2 cells will be added.
CPT Code(s): 86038 ANA; if reflexed, add 86039 ANA titer if positive; 83516 F-Actin IgG; 86376 LKM-1 IgG; 83516 AMA
 
 

 

 

 
All ARUP Sites:        www.aruplab.com     ·     www.arupconsult.com     ·     www.arup.utah.edu     ·     www.childx.org     ·     www.utahblood.org