ARUP's Laboratory Test Directory

Complement Factor B : 0051720

Mnemonic: COMP FAC B

Methodology: Quantitative Radial Immunodiffusion
Performed: Mon, Wed, Fri
Reported: 1-4 days
Specimen Required: Collect: Serum separator tube.

Specimen Preparation: Allow specimen to clot for 30 minutes to one hour at refrigerated temperature. Separate serum from cells ASAP or within 2 hours of collection. Transfer 1 mL serum to an ARUP Standard Transport Tube and place on refrigerant pack or freeze immediately. (Min: 0.3 mL)

Storage/Transport Temperature: Frozen.

Unacceptable Conditions: Room temperature specimens. Specimens exposed to repeated freeze/thaw cycles.

Stability (collection to initiation of testing): After separation from cells: Ambient: Unacceptable, Refrigerated: 48 hours; Frozen: 1 year

Reference Interval:
20-51 mg/dL
Interpretive Data:

See Compliance Statement D: www.aruplab.com/CS
CPT Code(s): 86160
Cross References: Properdin Factor B (Complement Factor B)