ARUP's Laboratory Test Directory
| 0050398: Mycoplasma pneumoniae Antibody, IgM |
| Test Mnemonic: MYCO-M | |
|
#ExistMethodology>
Methodology: Enzyme-Linked Immunosorbent Assay
*ExistMethodology> #ExistPerformed> Performed: Sun-Sat *ExistPerformed> #ExistReported> Reported: 1-3 days *ExistReported> |
| Specimen Required: | |
|
#ExistCollect>
Collect: One 4 mL SST.
*ExistCollect> #ExistTransport> Transport: 0.5 mL serum at 2-8°C. (Min: 0.2 mL) Submit specimen in an ARUP Standard Transport Tube. *ExistTransport> #ExistPedCollectTransport> Pediatric Collection/Transport: 0.1 mL serum at 2-8°C. *ExistPedCollectTransport> #ExistRemarks> Remarks: Separate serum from cells ASAP. Acute and convalescent specimens must be labeled as such; parallel testing is preferred and convalescent specimens must be received within 30 days from receipt of the acute specimens. Please mark specimen plainly as "acute" or "convalescent." *ExistRemarks> #ExistConditions> Unacceptable Conditions: Severely lipemic, contaminated, heat-inactivated, icteric or hemolyzed specimens. *ExistConditions> #ExistStability> Stability: After separation from cells: Ambient: 2 days; Refrigerated: 2 weeks; Frozen: 1 year (avoid repeated freeze/thaw cycles) *ExistStability> |
|
| Reference Interval: |
|
#ExistRefRange> 0.76 U/L or less: Negative - No clinically significant amount of M. pneumoniae IgM antibody detected. 0.77-0.95 U/L: Low Positive - M. pneumoniae-specific IgM presumptively detected. Collection of a follow-up sample in one to two weeks is recommended to assure reactivity. 0.96 U/L or greater: Positive - Highly significant amount of M. pneumoniae-specific IgM antibody detected. However, low levels of IgM antibodies may occasionally persist for more than 12 months post-infection. *ExistRefRange> |
| CPT Code(s): | |
| 86738 |